failOnBindError

Treat a failed TCP listener as a module activation failure.

Name:

failOnBindError

Scope:

module

Type:

boolean

Default:

off

Required?:

no

When enabled, failure to open any configured imtcp listener makes module activation fail. With global(abortOnUncleanConfig="on"), rsyslog then stops during startup. By default, rsyslog reports the failed port and keeps working with any listeners that opened successfully.

For address-in-use bind failures, the diagnostic names one visible Linux process holding a listener on the port when procfs permissions permit it. That process may use a different local address, and socket ownership may change between the bind attempt and lookup. If no owner is visible on Linux, the diagnostic suggests an ss command to run with appropriate permissions.

global(abortOnUncleanConfig="on")
module(load="imtcp" failOnBindError="on")
input(type="imtcp" address="127.0.0.1" port="6514")
version: 2
global:
  abortOnUncleanConfig: "on"
modules:
  - load: imtcp
    failOnBindError: "on"
inputs:
  - type: imtcp
    address: "127.0.0.1"
    port: "6514"